Search results for " image enhancement"
showing 10 items of 50 documents
Non-invasive determination of cartilage thickness throughout joint surfaces using magnetic resonance imaging.
1997
Abstract Data on articular cartilage thickness in the living are important for the design of computer models, aimed at preoperatively assessing the effect of surgical procedures on joint contact and load transmission, and for the calculation of cartilage material properties from its deformational behavior as determined during arthroscopy. A non-invasive method for measuring cartilage thickness in living subjects is, however, not available. A technique based on magnetic resonance imaging has therefore been tested for assessing articular cartilage thickness throughout joint surfaces. The accuracy is determined by comparing cartilage thickness maps obtained from three patellar specimens with a…
MAGIC-5: an Italian mammographic database of digitised images for research
2008
The implementation of a database of digitised mammograms is discussed. The digitised images were collected beginning in 1999 by a community of physicists in collaboration with radiologists in several Italian hospitals as a first step in developing and implementing a computer-aided detection (CAD) system. All 3,369 mammograms were collected from 967 patients and classified according to lesion type and morphology, breast tissue and pathology type. A dedicated graphical user interface was developed to visualise and process mammograms to support the medical diagnosis directly on a high-resolution screen. The database has been the starting point for developing other medical imaging applications,…
Analysis of different contrast enhancement patterns after microbubble-based contrast agent injection in liver hemangiomas with atypical appearance on…
2006
BACKGROUND: We describe different possible enhancement patterns in liver hemangiomas with atypical appearance on baseline ultrasound after microbubble-based contrast agent injection. METHODS: From a series of 253 consecutive lesions that were indeterminate on baseline ultrasound and then scanned after injection of air-filled microbubble contrast agent, 65 focal liver lesions were retrospectively selected on the basis of a diagnosis of liver hemangioma on multiphase contrast-enhanced computed tomography (n = 23), magnetic resonance imaging (n = 27), or histology (n = 15). Each lesion was scanned during arterial phase (30 s after microbubble injection) and late phase (5 min after injection). …
Tumori gastrointestinali stromali: Aspetti con tomografia computerizzata multidetettore (40-strati)
2006
Purpose. The purpose of this study was to describe the findings and evaluate the role of multidetector (40-slice) computed tomography (MDCT) in the preoperative assessment of gastrointestinal stromal tumours (GISTs). Materials and methods. Thirteen patients with histologically proven GIST (size: 4-30 cm; mean: 9 cm) underwent 40-slice MDCT after the ingestion of 1,000 ml of water. Images were obtained before and 70 s after intravenous injection of 120 ml of iodinated contrast agent. Two experienced radiologists reviewed the CT findings to evaluate lesion site, size, margins, attenuation, growth pattern, enhancement pattern, ascites, lymphadenopathy, direct invasion to adjacent organs and di…
TC perfusionale nell'ischemia cerebrale acuta: Valore predittivo dei parametri di perfusione cerebrale nel discriminare il tessuto vitale da quello i…
2007
Purpose. The aim of this study was to assess the value of computed tomography (CT) perfusion parameters in differentiating tissue viability in acute stoke patients. Materials and methods. Thirteen patients (mean age 63.3 years) with nonhaemorrhagic stroke underwent multidetector perfusion CT within 3 h of symptom onset. Images were continuously acquired at the basal ganglia over 40 s during injection of 90 ml of iodinated contrast medium injected at a rate of 9 ml/s with a 9-s delay. Z-axis coverage was 20 mm. All patients underwent diffusion-weighted magnetic resonance imaging (DWI) within 12 h of perfusion CT to define the extent of the infarct. Perfusion CT data were analysed in regions …
[Esophageal digital videofluorography with water siphon test in the post-operative evaluation of the anti-reflux laparoscopic surgery].
2004
Background: In recent years digital videoefluorography (VFG) with water siphon test (WST) has been proposed just for diagnosing biatal bernia and/or gastroesophageal reflux. Patients and Methods: Fifteen patients undergone Laparoscopic Nissen (LN) for complicated GFRD associated to biatal bernia, were referred for VFG and WST in order to evaluate the functional results of surgery. At one- month videofluorographic control thirteen patients had just a minimal prolonged esophageal transit time hut only six of these had an early postoperative dysphagia, whereas at six montJh control the prolonged esophageal transit time was present in three patients two of which complained a very light dysphagi…
The effect of balloon dilatation on post-stenotic myocardial perfusion before and after stimulation of coronary flow reserve: evaluation by the densi…
1988
From densitometric evaluation of digital subtraction cineangiocardiograms the parameter 'Mean Rise Time' (MRT), defined as the time from the onset of local myocardial contrast medium opacification to the point of maximal opacification can be derived; this parameter revealed a close correlation with the results on myocardial perfusion obtained by Thallium-201 scintigraphy. A prolonged 'Mean Rise Time' was indicative of an impairment of myocardial perfusion. We have developed a heart-phase gated real-time digitization procedure and computer-supported method for the densitometric estimation of the MRT to obtain information about the effect of coronary balloon dilatation on myocardial perfusion…
Diagnostic performance of gadobenate dimeglumine enhanced MR angiography of the iliofemoral and calf arteries: a large-scale multicenter trial
2007
OBJECTIVE. The purpose of this study was to compare gadobenate dimeglumine–enhanced MR angiography and unenhanced time-of-flight MR angiography for the detection of significant peripheral arterial occlusive disease using digital subtraction angiography as our reference standard. SUBJECTS AND METHODS. Two hundred seventy-two patients underwent MR angiography and digital subtraction angiography of the iliofemoral arteries. MR angiography was performed before (2D time-of-flight acquisitions) and after (spoiled gradient-echo acquisitions) the administration of 0.1 mmol/kg of gadobenate dimeglumine at 1–2 mL/s. Contrast-enhanced MR angiography and digital subtraction angiography of the calf arte…
Arterially enhancing liver lesions: significance of sustained enhancement on hepatic venous and delayed phase with magnetic resonance imaging.
2007
Benign hepatic vascular neoplasms and vascular pseudolesions are commonly encountered in magnetic resonance (MR) imaging. Most of these benign lesions demonstrate not only arterial-phase hyperintensity, but also persistent enhancement on venous and delayed imaging, unlike most malignant hepatic masses. These features, along with other MR findings and morphological characteristics, may allow for more confident diagnosis and distinction from hepatic malignancy. The objective of our study was to illustrate the MR imaging findings of hepatic lesions that demonstrate both early arterial and sustained enhancement on hepatic venous and delayed phase.
Value of contrast-enhanced MR angiography and helical CT angiography in chronic thromboembolic pulmonary hypertension.
2003
The aim of this study was to evaluate the diagnostic value of contrast-enhanced MR angiography (ce MRA) and helical CT angiography (CTA) of the pulmonary arteries in the preoperative workup of patients with chronic thromboembolic pulmonary hypertension (CTEPH). The ce MRA and CTA studies of 32 patients were included in this retrospective evaluation. Image quality was scored by two independent blinded observers. Data sets were assessed for number of patent segmental, subsegmental arteries, and number of vascular segments with thrombotic wall thickening, intraluminal webs, and abnormal proximal to distal tapering. Image quality for MRA/CTA was scored excellent in 16 of 16, good in 11 of 14, m…